See the direction, not just the number
Positive means air tends to flow out of the room; negative means it tends to flow in. Every reading is signed and charted, so a room drifting toward zero — or flipping — is obvious at a glance.
A wireless differential pressure monitor that measures the pressure difference between two spaces, streams it to a real-time dashboard with temperature and humidity alongside, and notifies you at the thresholds you set. Room pressure stops being a spot check and becomes a continuous record.
Representative image. Actual product may differ from what's shown.
Two pressure ports. One number. A history that never sleeps.
Whether a room sits positive or negative to its neighbour decides which way air moves through every door gap and pass-through. Doors open, filters load, exhaust fans cycle and dampers drift — and a room set up correctly last month can quietly read differently today. A gauge on the wall only tells you what it says when someone looks.
Positive means air tends to flow out of the room; negative means it tends to flow in. Every reading is signed and charted, so a room drifting toward zero — or flipping — is obvious at a glance.
Compare the pressure trace with door traffic, filter changes, exhaust schedules and other events, so whoever looks after the room can see exactly when a change began.
Every reading and every threshold crossing is time-stamped and stored. Chart it, export it as CSV or pull it through the API when someone asks what the room was doing last Tuesday.
A compact wireless differential pressure sensor with the range, resolution and connectivity to sit between any two spaces — and the same Aretas IoT Cloud that runs our whole sensor line.
0.08 Pa zero-point accuracy on the standard ±125 Pa range, with 16-bit resolution, so you can see the small, slow drifts that matter in tightly balanced rooms.
Choose ±125 Pa or ±500 Pa to match the job, from gentle room-to-corridor cascades to ducts, plenums and mechanical spaces.
2.4 GHz Wi-Fi straight to the cloud or a local Aretas Gateway, or 900 MHz / 2.4 GHz XBee / Zigbee. No network drops needed at every door.
Alert when the differential goes above or below a user-defined threshold for longer than your hold time. SMS and email go out naming the monitor and the reading.
Add an on-device display of the current reading and an audible indicator. Set its threshold, whether it sounds above or below it, and how long the reading must stay there first.
Temperature and humidity are built into every unit. Add barometric pressure, pitot airspeed or electrostatic airflow sensing: same device family, same dashboard.
Fix the monitor on one side of the wall and run a reference tube to the adjacent space. Power it by DC adapter or USB power adapter. No conduit, no network drop.
The monitor joins your Wi-Fi or an Aretas wireless network and sends a signed differential pressure reading on the schedule you configure (every two minutes by default).
Real-time dashboards, trend lines and threshold alerts on any phone, tablet or PC. Spot a drift as it starts, and keep the full history for whoever looks after the space.
Every Differential Pressure Monitor includes access to the Aretas IoT Cloud — the same platform that powers our full sensor line. No per-seat licenses, no surprise add-ons.
Need a configuration you don't see here? Most of our deployments include some customization — ask us.
Track pressure between rooms, corridors and mechanical spaces. Spot trends and keep a time-stamped history to share with your mechanical contractor or consultant.
Monitor pressure between compounding rooms, anterooms and adjacent areas around the clock, with a time-stamped history you can chart and export.
Trend room-to-room pressure cascades continuously instead of between walkthroughs, and keep the data for your own quality records.
Fume hoods, high-capacity exhaust and fresh-air intakes all push room pressure around. See how each one moves the reading, hour by hour.
Rooms and containers designed to run positive can drift as filters load. Watch the margin and get notified at your threshold.
Pressurized electrical and control rooms in sawmills, grain handling and food processing — track the room-to-plant differential and its history from anywhere.
A room at positive differential pressure sits higher than its neighbour, so air tends to flow out of it. A room at negative differential pressure sits lower, so air tends to flow in. The monitor reports a signed value, so you always know which side is higher and by how much.
Mount the unit on one side of the wall between the two spaces and run a reference tube to the other side. Connect power (DC adapter or USB power adapter), join it to your network, and readings appear in your dashboard. No wiring runs between the monitor and the cloud.
The standard ±125 Pa range (0.08 Pa zero-point accuracy) suits most room-to-room and room-to-corridor monitoring. A ±500 Pa range (0.1 Pa zero-point accuracy) is available for larger differentials such as ducts, plenums and mechanical spaces. Tell us what you're measuring and we'll help you pick.
No. As well as 2.4 GHz Wi-Fi, the monitor is available with 900 MHz or 2.4 GHz XBee / Zigbee radios, so units can reach an Aretas gateway in buildings with patchy coverage.
In the Aretas IoT Cloud, each alert rule watches for the differential going above or below a user-defined threshold and staying there for a hold time you choose, so a brief door opening needn't set it off. Want both a ceiling and a floor? Add one rule for each. When a rule fires, SMS and email notifications go out naming the monitor, the reading and the time. An optional on-device display and audible indicator are also available for awareness at the door.
Your readings stream to the Aretas IoT Cloud with long-term storage. The data is yours: view it, export it as CSV, or pull it into your BAS, CMMS or other systems through the REST API.
Tell us roughly how many room pairs you want to monitor and we'll send a quote — usually within one business day. Many sites start with the handful of rooms that matter most and expand from there.
Intended use: The Aretas Differential Pressure Monitor is a measurement and monitoring product. It measures, records and reports environmental conditions for general information and trend analysis. It is not a safety device and is not designed to control building systems or equipment. Readings, alerts and AI-generated summaries are informational only, and alerts depend on power, network and service availability. Aretas devices and software are not designed, marketed or warranted for safety-critical, life-safety, public-safety or building-control use. Aretas does not assess or certify whether any building, system or environment is safe or compliant; those decisions rest with the owner and their qualified professionals.
Tell us about your spaces and we'll send pricing plus a recommended product configuration — usually within one business day.